Kitchen exhaust and grease duct design selects hoods matched to the cooking equipment, calculates exhaust and makeup air rates, designs welded grease duct with code-required clearances and cleanouts, routes ductwork to code-compliant termination, and integrates fire suppression and controls.

I'm Jeremy Mills, CEO & Founder of Apex Grid Engineering and a U.S. Air Force veteran. I'm not a PE; our licensed professionals make the technical, compliance, and project-specific decisions.

Illustrative diagram of building MEP systems: ductwork with diffusers, an electrical panel with conduit, and piping runs.

The concise answer

Kitchen exhaust and grease duct design selects hoods matched to the cooking equipment, calculates exhaust and makeup air rates, designs welded grease duct with code-required clearances and cleanouts, routes ductwork to code-compliant termination, and integrates fire suppression and controls. The mental model that prevents kitchen ventilation failures: exhaust, makeup air, and fire protection are one system. Engineers who design the exhaust and leave makeup air to 'building air' create negative-pressure kitchens that don't ventilate. Engineers who design both but ignore the fire suppression interface create code problems. The hood, the duct, the makeup air unit, and the suppression system have to be designed together from the equipment list outward.

From appliance to rooftop

The design starts with the cooking equipment schedule — appliance by appliance, with duty ratings — because exhaust rates follow the equipment, not the kitchen size. Hood selection matches the appliance type and arrangement: wall canopy, island canopy, backshelf, each with capture velocities the design must achieve. The exhaust calculation sets the fan size; the makeup air calculation sets the replacement air, tempered where climate demands it, delivered so it doesn't disrupt hood capture. The duct design is where the fire code takes over: welded black steel, liquid-tight, pitched to drain grease toward collection, with cleanouts at every turn and rated enclosures or clearances through the building. Termination matters too — the exhaust must discharge above the roof with clearances from intakes, property lines, and operable windows, because grease-laden exhaust near an air intake is both a nuisance and a contamination problem. Controls tie it together: interlocks that start exhaust with the cooking equipment, and in many jurisdictions demand-control ventilation that ramps fans with actual cooking activity to save energy.

Designing kitchens that ventilate and pass inspection

Kitchen exhaust is one of the most inspected systems in a building, and plan reviewers know exactly where the weak designs are. These are the items that keep a kitchen project clean.

  • Start from the equipment list: exhaust rates and hood types follow the actual appliances, not rules of thumb
  • Design makeup air as part of the system: tempered replacement air, delivered without disrupting hood capture
  • Detail the grease duct completely: welded construction, clearances or rated enclosures, cleanouts at every change of direction
  • Route to a compliant termination: roof discharge with proper clearances from intakes, windows, and property lines
  • Coordinate suppression and controls: hood fire suppression interface, equipment interlocks, and demand-control ventilation

What else do project teams ask?

Why does grease duct have to be welded?
Because screws, rivets, and slip joints create interior obstructions where grease accumulates, and accumulated grease in a duct is fuel. Welded liquid-tight construction keeps the interior smooth so grease drains to collection points instead of building up. It's a fire safety requirement, not a fabrication preference.
What is makeup air and why does it matter?
Makeup air replaces the air the exhaust system removes. A commercial kitchen can exhaust thousands of cubic feet per minute — without dedicated makeup air, the kitchen goes deeply negative, which causes backdrafting of water heaters, dining room odors pulled into the kitchen, doors that won't open, and hoods that can't capture properly. The makeup air design is as important as the exhaust design.
How much clearance does grease duct need?
The code requires significant clearances between grease duct and combustible construction — commonly 18 inches — unless the duct is enclosed in a rated shaft or wrapped in a listed enclosure system. These clearances drive shaft layouts and ceiling space planning, which is why the duct routing needs to be designed early, not threaded through leftover ceiling space.
What are the cleaning access requirements?
Grease ducts need cleanout openings at every change of direction and at code-specified intervals, sized for a person to inspect and clean. The design has to place these where they're actually reachable — a cleanout above a finished hard ceiling with no access panel doesn't satisfy the intent. Cleanability is a design parameter, not a maintenance afterthought.

Ready to discuss your engineering scope?

Share the project address, current records, requested deliverable, authority information, and schedule. Apex Grid confirms professional responsibility, availability, and scope before work begins.

Request a Project Review

Get a quote on your project

Reviewed and sealed by licensed PEs. “Solid engineering and clear communication from start to finish.” — Jason Mitchell, Principal Architect

Tell us what you need and where the project is — quotes back within 12–24 hours on qualifying scopes.