Commercial kitchen make-up air design provides replacement air for kitchen exhaust hoods per the mechanical code: sizing make-up air units for the total exhaust volume, tempering the air for comfort and code, distributing it without disrupting hood capture, and balancing the kitchen slightly negative to the dining areas. The design coordinates with the hood exhaust and the building HVAC as one air-balance system.

I'm Jeremy Mills, CEO & Founder of Apex Grid Engineering and a U.S. Air Force veteran. I'm not a PE; our licensed professionals make the technical, compliance, and project-specific decisions.

Illustrative diagram of building MEP systems: ductwork with diffusers, an electrical panel with conduit, and piping runs.

The concise answer

Commercial kitchen make-up air design provides replacement air for kitchen exhaust hoods per the mechanical code: sizing make-up air units for the total exhaust volume, tempering the air for comfort and code, distributing it without disrupting hood capture, and balancing the kitchen slightly negative to the dining areas. The design coordinates with the hood exhaust and the building HVAC as one air-balance system. The air balance is the whole game. Too little make-up air and the kitchen starves; too much and cooking odors push into the dining room. The engineer calculates the balance explicitly — exhaust totals, make-up totals, transfer air from the dining area, and the resulting pressure relationship — and documents it. The health department and the building department both look at kitchen ventilation, so the design answers both.

Sizing, tempering, and distribution

Sizing starts with the hood schedule: each hood's exhaust rate per its listing and the cooking equipment beneath it. The make-up air total follows, typically replacing the large majority of the exhaust, with the small remainder made up by transfer air from adjacent spaces — which is what keeps the kitchen negative to dining. The unit gets selected for the airflow, the tempering load, and the filtration the application needs. Distribution is where good designs separate from bad. Make-up air dumped at high velocity near the hoods destroys their capture efficiency — the air curtain pushes effluent right past the filters. I distribute make-up air low and slow, away from the hoods: perforated diffusers, displacement-style delivery, or dedicated make-up plenums at the back of the cook line. The goal is replacing air without creating the cross-drafts that defeat the exhaust system.

Energy, controls, and the permit package

Conditioning thousands of cubic feet of outside air per minute is expensive, which is why the energy code cares about kitchen ventilation and why I design the controls thoughtfully. Demand-controlled kitchen ventilation — sensors that ramp hood exhaust and make-up air with actual cooking activity — cuts the energy penalty dramatically during idle periods. Heat recovery from the exhaust stream can preheat make-up air where the application allows. In California, the kitchen ventilation design documents to the 2025 California Energy Code (2025 Standards), effective January 1, 2026, including its kitchen exhaust and demand-control provisions. The permit package shows the hood exhaust design, the make-up air sizing and distribution, the air-balance calculations, the control sequences, and the energy compliance — the complete kitchen air system, engineered as one.

  • Air balance: make-up air sized to exhaust, kitchen held slightly negative to dining
  • Tempering: heated/cooled make-up air for comfort, code, and energy compliance
  • Distribution: low-velocity delivery away from hoods to protect capture efficiency
  • Demand control: sensor-based modulation cutting energy during idle cooking periods
  • Coordination: hood exhaust, make-up air, and building HVAC as one balanced system

What else do project teams ask?

What happens without enough make-up air?
The kitchen pulls air from anywhere it can — under doors, through the dining room, down the flues — creating drafts, slamming doors, and backdrafting gas appliances, which is a carbon monoxide hazard. Hood capture also degrades because cross-drafts pull cooking effluent out from under the hood. Starved kitchens are uncomfortable, unsafe, and fail inspection.
Does make-up air have to be heated or cooled?
The code generally requires tempering when the make-up air volume is large, and comfort demands it regardless — dumping unconditioned outside air on the cook line is miserable and counterproductive. The tempering strategy depends on climate and energy code: direct-fired, indirect, or heat recovery from the exhaust stream. I size and select for the local climate and the energy code's requirements.
Does this guarantee permit approval?
No. Engineering documents support a defined project scope, while the authority having jurisdiction controls its interpretation, completeness decision, review queue, and approval.
What should I send for an initial review?
Send the project address, plain-language scope, current drawings, existing-condition records, relevant calculations or comments, schedule, and the authority or code information already available. The responsible engineer will identify gaps.

Ready to discuss your engineering scope?

Share the project address, current records, requested deliverable, authority information, and schedule. Apex Grid confirms professional responsibility, availability, and scope before work begins.

Request a Project Review

Get a quote on your project

Reviewed and sealed by licensed PEs. “Solid engineering and clear communication from start to finish.” — Jason Mitchell, Principal Architect

Tell us what you need and where the project is — quotes back within 12–24 hours on qualifying scopes.