How Is Commercial Kitchen Exhaust Hood Design Done to Code?
By Jeremy Mills, CEO & Founder, Apex Grid Engineering — USAF Veteran. · Updated 2026-09-15
Commercial kitchen hood design selects Type I or Type II hoods per the cooking equipment, sizes exhaust to the mechanical code, routes grease duct to the roof with required clearances and access, and coordinates fire suppression. It includes hood sizing and placement, exhaust fan selection, grease duct construction and routing, makeup air design, fuel shutoff interlocks, and structural support for rooftop equipment.
I'm Jeremy Mills, CEO & Founder of Apex Grid Engineering and a U.S. Air Force veteran. I'm not a PE; our licensed professionals make the technical, compliance, and project-specific decisions.
The concise answer
Commercial kitchen hood design selects Type I or Type II hoods per the cooking equipment, sizes exhaust to the mechanical code, routes grease duct to the roof with required clearances and access, and coordinates fire suppression. It includes hood sizing and placement, exhaust fan selection, grease duct construction and routing, makeup air design, fuel shutoff interlocks, and structural support for rooftop equipment. The hood over the cook line is the most code-scrutinized assembly in a commercial kitchen. The mechanical code, the fire code, and the health code all have something to say about it, and the design has to satisfy all three simultaneously.
From equipment schedule to duct on the roof
The design sequence matters. First the equipment schedule gets classified appliance by appliance — which ones produce grease, which produce only heat and moisture — because that classification drives everything downstream. Then hoods get sized to overhang the equipment per the code, exhaust rates get calculated, and the duct routing gets drawn in three dimensions to the roof. Grease duct is where the detailing gets serious. The code requires specific construction — welded steel of minimum gauge — clearances to combustibles or listed enclosure assemblies, access panels for cleaning at every change of direction, and a continuous slope back toward the hood. I've seen duct routes drawn on a plan that were physically impossible in the ceiling space above, which is why the duct gets coordinated with structure, plumbing, and electrical before anyone fabricates anything.
The systems around the hood
The hood doesn't work alone. The supporting systems below are what make it capture, what make it safe, and what keep the building standing around it. Each one needs explicit design ownership.
- Makeup air: dedicated unit sized to the exhaust total, tempered, and interlocked with the exhaust fans
- Fire suppression: listed system covering hood, duct, and appliances, interlocked to fuel and power shutoff
- Rooftop support: curbs, structural framing, and seismic anchorage for exhaust fans and makeup air units
- Gas and electrical interlocks: automatic fuel shutoff on suppression discharge, wired and documented
- Cleaning access: duct access panels and roof access for the hood cleaning contractor the code requires
Which related engineering resources can help?
What else do project teams ask?
What's the difference between Type I and Type II hoods?
How is the exhaust rate determined?
What does the fire suppression system cover?
Why is makeup air such a big deal?