What Goes Into a Smoke Control Rational Analysis Report?
By Jeremy Mills, CEO & Founder, Apex Grid Engineering — USAF Veteran. · Updated 2026-09-15
A rational analysis documents the smoke control system's objectives, design calculations, equipment selection, control sequences, and acceptance testing for the fire marshal's review. It addresses stack effect, wind, and HVAC interactions, and for tall spaces typically includes smoke modeling proving tenability for the required egress time.
I'm Jeremy Mills, CEO & Founder of Apex Grid Engineering and a U.S. Air Force veteran. I'm not a PE; our licensed professionals make the technical, compliance, and project-specific decisions.
The concise answer
A rational analysis documents the smoke control system's objectives, design calculations, equipment selection, control sequences, and acceptance testing for the fire marshal's review. It addresses stack effect, wind, and HVAC interactions, and for tall spaces typically includes smoke modeling proving tenability for the required egress time. The report is the engineering argument that the system will work. Fire marshals approve arguments they can follow — with calculations, assumptions stated, and test criteria defined. A report that's just equipment schedules isn't an analysis.
What the analysis actually contains
A real rational analysis starts with the fire scenarios: where the fire is, how big it gets, what the smoke does. For an atrium, that means plume calculations or CFD modeling showing the smoke layer height over time against the egress time — proving occupants get out before the smoke comes down. For a pressurized stair, it means calculating the pressure differentials needed to keep smoke out with doors closed and with doors open during evacuation, accounting for the air that escapes through open doors. Then the report addresses the building's own air movement. Stack effect in a tall building can create pressure differences larger than the smoke control design values — the analysis proves the system works in both summer and winter conditions. Wind pressure on the facade, the HVAC system's normal operation, and the interaction between pressurization zones all get analyzed. Finally, the report specifies the controls: what the fire alarm triggers, the fan and damper sequences, the power supplies, and exactly how acceptance testing will verify each design value.
Writing an analysis the fire marshal approves
Fire marshals review these reports constantly, and they approve the ones that answer their questions before they're asked. What I put in every rational analysis.
- Clear objectives: what each system protects and the tenability criteria it must meet
- Stated assumptions: fire size, fuel, ambient conditions — everything the math depends on, on the record
- Environmental forces addressed: stack effect, wind, and HVAC interaction analyzed, not ignored
- Complete sequences: every fan, damper, and control action mapped to its fire alarm trigger
- Testable criteria: acceptance test procedures with pass/fail values tied to the analysis
Which related engineering resources can help?
What else do project teams ask?
When is a rational analysis required?
What is the difference between pressurization and exhaust smoke control?
Why does stack effect matter for smoke control?
What does acceptance testing prove?