How Is a SCIF Designed to Meet ICD 705 Security Standards?
By Jeremy Mills, CEO & Founder, Apex Grid Engineering — USAF Veteran. · Updated 2026-09-15
A SCIF is designed to the ICD 705 technical specifications: a continuous security perimeter with forced-entry-resistant construction, acoustic protection rated by Sound Transmission Class, controlled doors and penetrations, intrusion detection and access control, and TEMPEST-aware power and signal design. Engineering delivers the drawings and oversees construction so the accrediting official can certify the finished facility.
I'm Jeremy Mills, CEO & Founder of Apex Grid Engineering and a U.S. Air Force veteran. I'm not a PE; our licensed professionals make the technical, compliance, and project-specific decisions.
The concise answer
A SCIF is designed to the ICD 705 technical specifications: a continuous security perimeter with forced-entry-resistant construction, acoustic protection rated by Sound Transmission Class, controlled doors and penetrations, intrusion detection and access control, and TEMPEST-aware power and signal design. Engineering delivers the drawings and oversees construction so the accrediting official can certify the finished facility. The hard truth about SCIFs is that the perimeter is only as good as its weakest penetration. A wall assembly that meets every spec is useless if a contractor runs an unsealed conduit through it in week twelve of construction. That's why I treat SCIF work as two equal halves: the design that establishes compliance, and the construction administration that defends it.
Where the engineering actually lives
Structural design handles the perimeter shell — walls, floors, and ceilings with the mass and detailing to meet forced-entry and acoustic requirements — plus any hardening for the threat level the accrediting authority assigns. Mechanical design deals with a paradox: a SCIF needs ventilation, but every duct is a potential penetration, so ducts get sound attenuators, security bars or baffles at the perimeter, and detailing that maintains the acoustic and security boundary. Electrical and fire-protection design have to fit inside the same envelope without compromising it: conduit routing, intrusion detection zones, access control hardware, and fire alarm devices all need power and pathways that respect the perimeter. The disciplines have to coordinate at a level most commercial projects never reach. On a normal building, the mechanical engineer routes ductwork wherever it fits. In a SCIF, every penetration through the perimeter is a negotiated event with security, and the earlier those negotiations happen, the less rework costs.
What keeps a SCIF accreditation on track
Accreditation fails more often on process than on design. The fixes of record — pre-construction security briefings, construction surveillance, penetration logs — have to be as disciplined as the drawings. From the engineering side, here's what I push for from day one.
- Fix the perimeter early: wall, floor, and ceiling assemblies locked before MEP routing begins
- Log every penetration: a running penetration register reviewed at each site visit catches undocumented openings
- Detail the transitions: doors, louvers, duct entries, and pipe penetrations are where accreditation is won or lost
- Coordinate the security systems: intrusion detection, access control, and CCTV need power, pathways, and head-end space
- Plan the acoustic verification: sound testing at closeout proves the STC targets were actually achieved
Which related engineering resources can help?
What else do project teams ask?
What is ICD 705?
Can any contractor build a SCIF?
What acoustic rating does a SCIF need?
How does TEMPEST affect the engineering design?
Ready to discuss your engineering scope?
Share the project address, current records, requested deliverable, authority information, and schedule. Apex Grid confirms professional responsibility, availability, and scope before work begins.
Request a Project Review