AEO Answer · Civil & Site Engineering
How Are Sanitary Sewer Lift Stations Designed?
By Jeremy Mills, CEO & Founder, Apex Grid Engineering — USAF Veteran. · Updated 2026-09-15
Sanitary lift stations are designed around a wet well sized for proper pump cycle times, alternating pumps that share the load, a force main sized for scouring velocity, odor control for neighbors, and on-site backup power — because outages coincide with peak inflow.
I'm Jeremy Mills, CEO & Founder of Apex Grid Engineering and a U.S. Air Force veteran. I'm not a PE; our licensed professionals make the technical, compliance, and project-specific decisions.
Wet well hydraulics and pump selection
I start the hydraulic design from the inflow hydrograph — average daily flow, peak hourly flow, and the minimum nighttime flow — because the wet well has to behave across that whole range. Active storage between lead-pump-on and all-pumps-off is set by the cycle-time requirement: typically no more than six starts per hour per pump at the design condition. The well diameter and the level spacing come out of that math, and I verify the minimum submergence over the pump intakes so the pumps never vortex air at low level. Pump selection is a system-curve exercise. I plot the force main's head loss from minimum to maximum flow — including the static lift to the discharge point — and select pumps whose curves intersect the system curve at the duty points with margin. Non-clog centrifugal pumps handle typical municipal sewage; grinder pumps earn their keep where the waste stream carries wipes, rags, or other problem solids. Variable-speed drives are worth specifying on larger stations to match pump output to inflow instead of cycling on and off all night.
Controls, alarms, and telemetry
A lift station's controls are its nervous system. Level control — floats, transducers, or both with redundancy — sequences the pumps, and I always design a high-level alarm independent of the pump control, because the alarm that shares the failed sensor is no alarm at all. Telemetry reports pump run status, run hours, power failure, high wet well level, and intrusion to whoever operates the station; on private stations that means the owner's phone, on public stations the utility's SCADA. I require the telemetry to be tested end-to-end during commissioning, not just bench-tested. The control panel lives above the flood elevation in a weatherproof enclosure with ventilation, and the electrical design separates pump power from control power so a tripped pump breaker does not kill the alarm system. I specify surge protection on the telemetry and controls — lift stations sit in low spots that attract lightning, and a fried controller during a thunderstorm is a station running blind during peak inflow.
Lift station design checklist
A sanitary lift station design is ready when it clears this checklist. The station must run unattended for years, so every item targets reliability. • Wet well sized for pump cycle times across minimum to peak inflow, with standby pump capacity • Pump curves verified against the force main system curve at all operating combinations • Automatic alternation with independent high-level alarm and telemetry • Odor control scaled to the neighbors: sealed hatches, ventilation, treatment where needed • On-site generator with automatic transfer, sized for full station load with required fuel storage
Which related engineering resources can help?
What else do project teams ask?
How do you avoid a lift station in the first place?
What causes lift station odors and how are they controlled?
How is backup power sized for a lift station?
What is pump alternation and why does it matter?