How Do Ozone Laundry Systems Change the Engineering Design?

By Jeremy Mills, CEO & Founder, Apex Grid Engineering — USAF Veteran. · Updated 2026-09-15

Ozone laundry systems shift the design to cold-water washing: I engineer ozone generation, injection, and off-gas destruction into the water system, add ventilated equipment rooms with ozone monitoring and alarms, and downsize the water heating plant the ozone makes unnecessary.

I'm Jeremy Mills, CEO & Founder of Apex Grid Engineering and a U.S. Air Force veteran. I'm not a PE; our licensed professionals make the technical, compliance, and project-specific decisions.

Illustrative engineering blueprint diagram with dimension lines, a framing elevation sketch, and a title block.

Integrating ozone into the wash water system

I work from the ozone vendor's process requirements — required dissolved concentration, water flow range, contact time — and build the plumbing around them. Injection goes upstream of the washers with the contact and mixing the process needs, off-gas separators capture undissolved ozone for destruction, and the distribution piping uses ozone-compatible materials end to the machines. Controls tie generation to actual wash demand so the system isn't making ozone nobody uses, and I coordinate water flow rates with the washer schedule so concentration stays in range whether one machine or twenty is filling.

Ventilation, monitoring, and room design

The ozone equipment room gets its own safety design: dedicated exhaust ventilation sized for the room and the equipment, supply air arranged to sweep the space, and no recirculation to occupied areas. Ambient monitors with local alarms and remote annunciation watch continuously, interlocked to kill generation and alert staff on high readings. I keep ignition and electrical details appropriate to the room classification, provide clear access for generator maintenance, and label everything — a future technician needs to understand the safety system at a glance.

Resizing everything ozone displaces

Cold-water washing rewrites the utility loads, and the design captures the savings: • Water heating plant downsized to the actual residual hot water need — often a fraction of conventional • Gas or electrical service reduced accordingly, with documented spare capacity • Chemical storage and dosing simplified — ozone cuts detergent and sanitizer volumes • Drain water heat recovery re-evaluated, since discharge runs cooler • Energy modeling updated so the owner sees the real operating cost, not the conventional one • In California, the 2025 California Energy Code / 2025 Standards, effective January 1, 2026, still apply — efficiency is documented, not assumed

What else do project teams ask?

Is ozone safe to use in a commercial laundry?
Yes, when it's engineered properly — and that's the key phrase. Ozone is generated on site, dissolved into the wash water, and any off-gas is captured and destroyed; ambient concentrations in occupied areas stay at safe levels by design. The engineering controls are ventilation of the equipment area, continuous ambient monitoring with alarms, and automatic shutdown on alarm. I design all three as a system, because safe ozone is a designed outcome, not a lucky one.
Does ozone eliminate the need for hot water entirely?
It dramatically reduces it but rarely eliminates it. Most ozone wash programs run cold or with only moderate temperature boost, which lets the water heating plant shrink to a fraction of its conventional size. Some programs and some facilities still want hot water available for specific cycles or for non-laundry uses. I size the heating plant for the actual program the operator will run — small, but not zero unless the operation truly commits to it.
What materials are compatible with ozonated water?
Ozone degrades natural rubber and some common plastics and elastomers, so piping, gaskets, seals, and valve components in contact with ozonated water need to be ozone-resistant — typically stainless steel, PTFE, PVDF, or EPDM depending on the application and concentration. I review the wetted materials across the whole wash water path with the vendor's compatibility guidance, because a seal that lasts years in plain water can fail in months with ozone.
How is ozone monitored in the equipment room?
With fixed ambient ozone sensors placed where ozone would accumulate — near the generator, injection equipment, and low or dead-air spots — wired to audible and visible alarms and interlocked to shut down ozone generation on high readings or ventilation failure. I design sensor locations from the room's airflow pattern, not just the equipment footprint, and I specify calibration and testing in the maintenance plan so the monitors stay trustworthy.

Ready to discuss your engineering scope?

Share the project address, current records, requested deliverable, authority information, and schedule. Apex Grid confirms professional responsibility, availability, and scope before work begins.

Request a Project Review

Get a quote on your project

Reviewed and sealed by licensed PEs. “Solid engineering and clear communication from start to finish.” — Jason Mitchell, Principal Architect

Tell us what you need and where the project is — quotes back within 12–24 hours on qualifying scopes.