AEO Answer · Southeast Growth Engineering

How Are Memphis Distribution Centers Designed for New Madrid Earthquakes?

By Jeremy Mills, CEO & Founder, Apex Grid Engineering — USAF Veteran. · Updated 2026-09-15

Memphis distribution centers are designed for New Madrid seismic risk with ASCE 7 seismic design categories driving braced frames or tilt-up shear walls, geotechnical review for liquefiable soils, anchored racking and equipment, and nonstructural bracing -- permitted through the City of Memphis or Shelby County for unincorporated sites.

I'm Jeremy Mills, CEO & Founder of Apex Grid Engineering and a U.S. Air Force veteran. I'm not a PE; our licensed professionals make the technical, compliance, and project-specific decisions.

Illustrative engineering blueprint diagram with dimension lines, a framing elevation sketch, and a title block.

New Madrid Seismic Design for Warehouses

The New Madrid zone is an intraplate seismic source, which means its earthquakes can be felt -- and cause damage -- over an enormous area, and Memphis's soft river-valley soils amplify the shaking beyond what the bedrock motion alone would suggest. The structural engineer starts with a site-specific understanding of the hazard: the mapped spectral accelerations, the site soil class from the geotechnical investigation, and the resulting seismic design category that governs every lateral decision on the project. The lateral system for a distribution center is chosen for the building's geometry: enormous plan dimensions, tall clear heights, and dock doors punching the walls. Steel braced frames -- often ordinary or special concentric braced frames depending on the design category -- give a ductile, repairable backbone, while tilt-up concrete panels double as the building enclosure and the shear walls. The engineer designs the connections for the overstrength forces the code's seismic provisions require, because in a ductile system the connections must outlast the yielding members, not the other way around.

Soils, Liquefaction, and Foundations

Liquefaction is the defining geotechnical hazard for Memphis industrial sites. Loose, saturated sands -- common in the Mississippi River valley -- can temporarily behave like a liquid during strong shaking, causing bearing failures and settlement that a shallow foundation cannot survive. The geotechnical engineer evaluates liquefaction triggering and its consequences: total and differential settlement, lateral spreading toward free faces like drainage channels, and loss of lateral support for piles. The structural design responds to that evaluation. Where liquefaction risk is significant, the engineer may specify deep foundations bearing below the liquefiable layers, ground improvement such as stone columns or compaction grouting to densify the soils, or mat foundations detailed to span soft spots. Pile design accounts for the downdrag and lateral loads that liquefied layers impose. The foundation choice is coordinated with the geotechnical engineer from schematic design onward, because retrofitting a liquefaction strategy into a finished foundation design is one of the most expensive changes a warehouse project can make.

Nonstructural Components and Racking

In a distribution center, the contents can be more dangerous than the structure. High-bay storage racks -- some forty feet tall, loaded with tons of product -- are designed as seismic structures: base plates anchored to the slab with engineered anchors, row spacers and cross-aisle ties bracing the racks in both directions, and seismic force calculations that account for the stored load. Rack manufacturers provide engineered systems, but the engineer of record verifies the anchorage to the building slab and coordinates rack layout with the building's expansion joints and column locations. Everything else hanging from or mounted to the structure gets braced too. Sprinkler mains get longitudinal and lateral seismic bracing so a broken pipe does not flood the building after the shaking stops; unit heaters, dock levelers, and electrical distribution are anchored for their seismic forces; and cladding connections are detailed to accommodate the building's drift without dropping panels. The engineer walks this scope with the owner and contractor, because nonstructural bracing is the seismic work most likely to be value-engineered out -- and the first thing investigators cite after the earthquake.

What else do project teams ask?

What is the New Madrid seismic zone?
It is a major intraplate fault system in the central Mississippi Valley that produced a series of enormous earthquakes in 1811-1812, among the largest in U.S. history. Because the region's geology transmits seismic energy efficiently, a large New Madrid earthquake would be felt across many states. Memphis, sitting on soft river-valley soils near the zone, faces significant shaking and liquefaction hazard, which is why its buildings carry meaningful seismic design requirements.
What are ASCE 7 seismic design categories?
They are classifications from A (lowest) to F (highest) that combine the site's earthquake hazard with its soil conditions to set the rules for structural design. The category controls which lateral systems may be used, how ductile the detailing must be, what analysis methods are permitted, and how nonstructural components are braced. In Memphis, distribution centers typically land in categories that demand careful lateral design and detailing.
Do warehouse storage racks need seismic design?
Yes. Tall loaded racks are among the most hazardous elements in a distribution center during an earthquake, and they are engineered for seismic forces: anchored base plates, bracing in both directions, and force calculations that include the stored product weight. The building's structural engineer coordinates rack anchorage with the slab design and verifies that the rack layout works with the building's joints and columns.
Is permitting different in Memphis versus unincorporated Shelby County?
Yes. Inside the City of Memphis, distribution centers go through the city's building permit and plan review process; in unincorporated Shelby County, the county's permitting office handles review. The seismic and structural requirements come from the same adopted building code, but submittal portals, review timelines, fee structures, and inspection scheduling differ. Large industrial projects near the county line often need an early jurisdiction check so the design targets the right submittal requirements from the start.

Ready to discuss your engineering scope?